CSL-COM10 Comet Assay Tank for 10 Slides
CSL-COM20 Comet Assay Tank for 20 Slides
CSL-COM40 Comet Assay Tank for 40 Slides
CSL-COM80 Comet Assay Tank for 80 Slides
CSL-CHILLER Chiller unit for active slide temperature control
Comet Assay IV DNA damage and repair software scoring system
(contact sales@cleaverscientific.com)
F250 Julabo Chiller
Ordering Information
For Single Cell Gel Electrophoresis
Minimise exposure to light and reduce
background DNA damage
High efficiency cooling for enhanced
resolution
comet assay tanks
The Comet Assay
Background: First introduced in 1981 to quantify double-stranded DNA breakages in single cells
exposed to γ-irradiation, the Comet Assay (or SCGE) has since been adapted to analyse specific DNA
lesions and repair processes.
Overview: Following genotoxic insult, such as ionizing radiation, the resultant strand breakage of
supercoiled duplex DNA reduces the size of the large genomic DNA from which these strands are
separated or drawn out by electrophoresis. The genomic DNA then takes on the appearance of a
‘comet’ as its negatively charged broken ends and fragments migrate towards the anode during
electrophoresis.
Method: After exposure to a genotoxic insult cells are suspended within low melting point agarose and
embedded within a thin layer of agarose on a microscope slide. Cellular protein is then removed by lysis
in detergent, when DNA is allowed to unwind in alkaline conditions before electrophoresis. The DNA is
electrophoresed, stained and then analysed using software such as Perceptive Instruments Comet
Assay IV.
Results: Microscopy imaging is used to measure DNA fluorescence upon staining. In DNA damaged
cells the resultant image resembles a ‘comet’ with the cellular DNA separated into a head and tail. The
head is mainly composed of intact genomic DNA, whereas any fragmented or damaged DNA is
concentrated within and towards the tail.
Cleaver Scientific recommends Comet Assay IV scoring software from Perceptive Instruments. Please
enquire by emailing [email protected].
Cleaver Scientific COMET assay tanks are available in four slide formats to study single cell gel
electrophoresis (SCGE), a technique made popular by drug toxicology and carcinogenesis studies for the
detection and quantitation of DNA damage in cells. Each tank’s robust construction from ebony acrylic
ensures that cells remain free of exposure to background light and DNA damage during electrophoresis,
while a cooled central platform provides a convenient surface for slide preparation and control of slide
temperature during the assay. Following electrophoresis DNA damage may be measured using the
highly recommended Comet Assay IV Software from Perceptive Instruments.
F250 Chiller
With PID control ensuring temperature stability within ±0.5°C, the F250 is the perfect recirculating
chiller for active slide temperature control. This chiller also benefits from a maximum flow rate of 15
litres per minute and 0.35 bar pressure, while a small footprint and frontal vents allow multiple units to
be aligned side-by-side if required. A versatile working temperature range of +5°C to +40°C makes the
chiller suitable for use in other applications such as flat-bed isoelectric focusing.
Full Screen Shot of a Comet Profile within the Comet Assay
IV Software.
A. The Comet ‘Head’ comprising largely intact genomic DNA.
B. The Comet ‘Tail’ of mobile damaged or fragmented DNA.